Air Ozonation

Cigarette Smoke Removal
Fire Smoke Odor Control
Indoor Air Quality Solutions
Indoor Air Treatment
Industrial Air Treatment
Odor Removal Control
Operation Room Fumigation
Ozone for HVAC System
Restroom Odor Control
Sick Building Syndrome
VOC Removal
 

 Water Ozonation

Cooling Tower

Laundry water treatment

Drinking water treatment

Municipal water treatment

Sewage Treatment Plant

Grey Water Treatment

Swimming Pool

Pond Water Treatment

Aquaculture Water

Aquarium Water Treatment

Effluent Water Treatment

Sand Media Carbon Filter

Type II RO
 
 

Industry wise Solutions

Hospital

Hotel

Exhibition

Mall

Offices

Pharma

Packaging

Effects of Ozone
 

www.swimmingpoolwatertreatment.com www.chemtronicsindia.com www.waterpurificationindia.com www.reverseosmosiswatertreatment.com www.waterfiltrationindia.com

Company Profile

We are Manufacturer & Exporter of Ozone Generators ranging from 10gm/hr – 20000gm/hr, for Indoor Air Treatment, Water & Wastewater Treatment applications across all Sectors. An ISO 9001-2000 Company. Established in year 2004. We have ultra-modern manufacturing units located at Mumbai, Maharashtra, India. Being a truly professionally managed company, we boast a team of highly qualified professionals and trained workforce, which are experienced enough to efficiently handle large orders, even within the shortest possible lead time, strictly within the scheduled delivery time.

Today, our company has the perfect combination of technology, human resources and management team, where each one has the commitment to make a strong presence all across the globe. Our solution design is based on latest and time tested technology which serve green building partners seeking US Green Building Council (USGBC) LEED Certification point on Indoor Air Quality, Water Efficiency and Energy Efficiency. We provide Eco Sustainable solutions.

At Chemtronics, we strictly adhere to Indian/International industry standards as prescribed by WHO, US EPA, German DIN Standards, Australian NSW Standards. Our equipments are recognized by EPC & MEP Company for flawless performance, which is the result of continuous research and development, & stringent quality control.
 

Business Philosophy : -

The core of our Business Philosophy revolves around the manufacturing of environmentally-safe products with world class technology, ensuring on time delivery and reasonable cost – offering value for money to our customers, while enhancing the safety and development of our customers. At Chemtronics, we strictly adhere to industry standards and our ozone generators are recognised for flawless performance, which is the result of continuous research and development, up gradation of technology and stringent quality control as per ISO guidelines.

for INDOOR AIR TREATMENT: -

for WATER TREATMENT: -

for WASTE WATER TREATMENT: -

• AHU Air Ozonation

• Odour removal

• Air Disinfection

• Air Purification

• Volatile Organic Compound Reduction

• Indoor Air Quality (IAQ)

• Sick Building Syndromes (SBS)

• Operation Theatre Fumigation

• Production Process Air Treatment

• Packing Process Air Treatment

• Swimming Pool Water Treatment

• Drinking Water Treatment

• Process Water Treatment

• Laundry Water Treatment

• Cooling Tower Water Treatment

• River/Lake/Dam Water Treatment

• Ground Water Treatment

• Sea Water Desalination

• Gray Water Treatment
 
• Sewage Treatment Plant
 
• Skid mounted Sewage  Treatment Plant

• Containerized Sewage  Treatment Plant
 
• Portable Sewage  Treatment Plant

Design & Built Matrix:

Indoor Air Treatment / Air Ozonation :

1. AHU Air Ozonation – 10 gr/hr – 10,000 gr/hr

Water Treatment :-

1 Surface Water Treatment – 100 KLD – 100 MLD

2 Brackish Water Treatment - 100 KLD – 100 MLD

3 Sea Water Desalination - 100 KLD – 10 MLD

4 Swimming Pool Water Treatment & Ozonation - 0.5 ML – 10 ML

5 Cooling Tower Water Treatment & Ozonation - 1,000 m3/hr – 100,000 m3/hr

6 Laundry Water Ozonation - 50 Kg – 500 Kg

Waste Water Treatment & Recycle : -

1. Gray Water Treatment For Reuse - 100 KLD – 10 MLD

2. Sewage Treatment For Reuse - 100 KLD – 2 MLD

3. Effluent Water Treatment Plant - 100 KLD – 1 MLD

* All above solutions are also available on skid mounted or containerized


 

Tenders Specification

 

1. Ozone generated shall produce minimum of 6-8% wt/wt of oxygen.
2. Feed gas to ozonator should strictly be medical grade oxygen. Air as feed gas is not permissible & shall not be used.
3. Capacity of ozone generator & ozone production should be specified in gr/hr.
4. Ozone generator should be sized as to dose 1.0 ppm of ozone.
5. Ozone generator should generate medical grade ozone, free from any impurities & by products.
6. NOx or Nitric acid should not be generated, by ozone generator.
7. Each ozone generator should operate automatically using sensors & interlocked by ozone sensor.
8. Residual ozone going into occupied room should not be more than 0.04 ppm.
9. Ozone gas should be injected in return air duct only.
10. Ozone generator should able to inject ozone gas in mainstream or side stream.
11. Ozonator or any of its part should not hamper the flow of the air, by creating obstruction in a way.
12. Ozone generation & variation of ozone output shall be at variable frequency. Modulation of ozone at constant frequency is not permissible.
13. Ozone generator equipment shall be housed outside the AHU duct. The ozone generator shall be floor/skid mounted with integrally piped & wired.
14. Ozone generator cell shall be fabricated of High purity aluminium.
a. Cylinder :Should be Teflon coated for long life
b. Gasket : should be made from ozone compatible material.
c. Dielectric: tubes shall be fabricated of ceramic or high purity quartz to provide high voltage & high efficiency dielectric.
15. All pipes & accessories in contact with ozone shall be ozone compatible.
16. Ozone power density shall not exceed 0.30 watts per sq. cm of effective dielectric surface area.
17. Power supply unit transformers shall be dry type, class F insulated with high temperature cut-out for each phase, suitable for operation in 104degree F (40 degree C) ambient, with temperature rise not higher than 122 degree F (50degree C).
18. The PSU shall consist of the following components as a minimum, all factory wired, assembled and tested.
• Single Phase harmonic filter to minimize total harmonic distortion.
• Three phase isolating transformer.
• Three phase fully controlled rectifier with snubbers and MOV’s (Metal Oxide Varistors) on each side.
• DC filter bank.
• IGBT inverter assembly complete with snubbers.
• Medium frequency oscillating circuit with over current and over voltage protection.
• Medium frequency dry-type transformer.
19. If operation is on medium frequency, each power supply unit shall have frequency electronic protection consisting rectifiers or invertors over current protection, over current protection, over voltage protection at the IGBT modules, and high voltage short circuit protection.
20. The Ozone generator shall be provided with emergency stop button.
21. Energy saving intake of fresh air from outside for dilution should be reduced (by about 50 - 80 %)

 